- Description
-
- Commodity name: Double Cabin Outdoor Cabinet
- Commodity ID: 1230157714315431936
Structure and Layout
Features
• Modularization design
• Flexible and easy to acquire site
• Carrier-class design and reliability
• Subdivision temperature control help to save energy
Value of Customer
• Rapid deployment, rapid establishment
• Saving land resource
• Saving maintenance cost
• Reducing site energy consumption
Mechanical parameters
Description
Value
External dimensions of the cabinet
2100mm(H) × 905mm (W) × 1135mm (D)
Internal dimensions of the cabinet
1800mm (H) ×800mm (W) ×800mm (D)
Base Size
200mm (H) × 900mm (W) ×900mm (D)
Weight
200KG (excluding devices and batteries)
Wall thickness
45mm
Configuration list
Cabinet parameters
User space
Equipment compartment
Battery compartment
11U power supply space, 10U reserved device space
2*8U,12V 150AH battery(2 string)
Protection class
IP55
Working temperature and humidity
-40~50(℃), 5% ~100% (20 ℃ ± 5 ℃)
Storage temperature
-40~70(℃)
Atmospheric pressure
62KPa~106KPa
The shipping form
Container transportation
Power Information(Optional)
capacity
200A
300A
600A
Power standard
Three-phase 380V 220V single phase compatible
The output voltage
220V / 380V, 45Hz ~65Hz
Height
5~9U
9~11U
10~13U
Lightning Performance
Class B + C Class AC, DC level D
The capacity of the power supply module
50A
50A
50A
Power Module Number
2-4
2-6
2 to 12
Efficiency Power Module
0.92 / 0.96
0.92 / 0.96
0.92 / 0.96
AC input CB
63A / 3P × 2 mechanically interlocked
100A / 3P × 2 mechanically interlocked
AC output breaker
32A / 1P × 2 10A / 1P × 2
32A / 1P × 4
DC output breaker
LLVD: 32A / 1P × 3,20A / 1P× 10
BLVD: 16A / 1P × 3
LLVD: 125A / 1P × 4
BLVD: 63A / 1P × 4,16A / 1P × 2
LLVD: 125A / 1P × 3
BLVD: 63A / 1P × 3,16A / 1P × 3
Battery breaker
125A / 1P × 4
Temperature control equipment(Optional)
Item
80W heat exchanger
190W heat exchanger
1500W air conditioning
500W air conditioning
200W Semiconductor air conditioning
Setting position
Equipment compartment
Equipment compartment
Equipment compartment
Battery compartment
Battery compartment
Key parameter
Power standard: DC-48V
Heat transfer efficiency: 80W / K
Power standard:
DC -48V
Heat transfer efficiency: 190W / K
Power standard:
AC 220V
Cooling Efficiency: 1500W
Power standard:
AC 220V
Cooling Efficiency: 500W
Power standard:
DC -48V
Cooling Efficiency: 200W
Wiring unit(Optional)
Project
ODF
ODF
Parameter
12 core, 19inch 1U,The front line, Connector type : SC / FC
24 core, 19inch 2U,The front line, Connector type : SC / FC
Other information
Working light
-48V LED lights
Safety standard
IEC / EN / UL 60 950
EMC standards
EN 300 386-2
Cabinet certification
Tell Certification
Customer demand Remark
project
Cabinet height
Temperature control equipment
Power system
Monitoring system
Wiring unit
Battery
Remark
Customer demand